Question: I have a BMS with CAN option. I have a battery charger with CAN connector, I also have a dash board (display unit) with CAN option.  How can I make these components work together over the CAN bus?

Answer: In most cases you need a master CAN bus unit to make the equipment work together. Most of the CAN bus equipment is only either sending data (Read Only mode) or receiving commands (Write Only mode). This equipment has no additional logic to make decisions of operation for other equipment or to control it. The logic of the operation must be set by the master CAN bus unit.

Example:  BMS system is sending data (about the status of the battery pack). A ventilator with CAN input is only receiving data (turn on/off and the rotation speed). The BMS itself cannot manage the ventilator. There must be the CAN BUS master unit to process the data from the BMS over CAN and to decide if the temperature is over the limit and when the ventilator is to begin the operation. Then the CAN bus master unit i will send data to the ventilator over the CAN bus.