The large capacity Winston cells 700AH, 1000AH are equipped with multiple terminals. All terminals are mutually connected and there is no difference between them.

The terminals of the small cells like 40AH, 60AH, 100AH, 160AH can be used for continuous loads with rating up to 100 Amp currents.  The larger terminals of the 200AH cells to 400AH cells can withstand some 300 to 400 Amp currents. 

Please note that for high power applications with currents above 100Amp (continuous) the cabling and connector mounting must be realized in a very precise way with corresponding load rating.  

For high power applications, with continuous load demands, it is recommended to use multiple terminals. This is the purpose of the multiple terminals on the large 700AH and 1000AH cells. 

In simple words: if you have continuous power rating more than 100 Amp, we always suggest using the multiple terminals.